PRINTING RELATED

TOP > PRODUCTS / PRINTING > PRINTING RELATED > QRD SYSTEM

QRD SYSTEM

pdf
  • INDIVIDUALLY DIVIDED INK DUCTOR ROLLER SYSTEM
    AUTOMATIC INK DENSITY CONTROL BY COMPUTER Automatic ink density control device with new concept.
    Individually divided ink ductor roller is operated by air cylinder and contact time with ductor roller is control by computer.
    INSTALLATION EXAMPLE

  • QRD adopt time control system instead of conventional film thickness control system, therefore it has many merits such as enable to adjust ink quantity accurately with 0.1% of notch, needless of Zero-point adjustment, etc.

MERIT OF QRD

  • 1. Time control system

    • Enable to adjust ink quantity accurately with 0.1% notch.
    • Few ink density difference by ink viscosity.
    • Needless of Zero-point adjustment of blade and fountain.
    • Ink feeding can be completely stopped at 0% feed setting.
    • Inhibit vibration caused by the duct roller (No shock-streak)

  • 2. One-touch ink set-up system

    • Automatic, quick ink supply.
    • High accuracy and stable ink density shorten the printing loss for only 4 sheets.
    • Needless of ink adjustment of both ends of roller.

  • 3. Fountain roller is controlled by Inverter-motor

    • Completely follow up printing speed.
    • Can arrange ink on the machine.

  • 4. Control Panel

    • Few damage since using general-purpose sequencer.
    • Good durability by using general-purpose sequencer.
    • Operation is done by touch-panel easy to see, so no trouble occur.

  • 5. Needless to change ink fountain,
        easy maintenance, and low cost installation

    • Low cost since just change ink ductor rollers and operate fountain roller by inverter
    • Easy maintenance since unnecessary to change ink fountain

CONTACT US